EXTECH INSTRUMENTS EX510 CALIBRATION and EXTECH INSTRUMENTS EX510 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the EXTECH INSTRUMENTS EX510 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Multimeter DMM?
Shop for Comparable Products on our
 used Multimeter DMM page

 
   EXTECH INSTRUMENTS EX510   Description / Specification:    
EXTECH INSTRUMENTS EX510 9 Function Heavy Duty Industrial MultiMeter

The Extech EX510 9 Function Heavy Duty Industrial MultiMeter measures AC/DC Voltage, AC/DC Current, Resistance, Frequency (electrical & electronic), Diode Test, and Continuity. It features a rugged design for heavy duty use. Specifications. DC Voltage Ranges: 600mV, 6V, 60V, 600V, 1000V. DC Voltage Maximum Resolution: 0.1 mV. DC Voltage Accuracy: ± (0.09% reading + 2 digits). AC Voltage Ranges: 6V, 60V, 600V, 1000V. AC Voltage Maximum Resolution: 0.001 V. AC Voltage Accuracy: ±(1.0% reading + 3 dgts) @ 50 to 60Hz, ±(2.0% reading + 3 dgts) @ 40Hz to 1KHz. DC Current Ranges: 600µA, 6000µA, 60mA, 600mA, 6A, 10A. DC Current Maximum Resolution: 0.1 µA. DC Current Accuracy: ±(1.0% + 3d). AC Current Ranges: 600µA, 6000µA, 60mA, 600mA, 6A, 10A. AC Current Maximum Resolution: 0.1 µA. AC Current Accuracy: ±(1.5% + 3d) @ 40Hz to 1kHz. Resistance Ranges: 600, 6k, 60k, 600k, 6M, 40Mohm. Resistance Maximum Resolution: 0.1 ohm. Resistance Accuracy: 600, 6k, 60k, 600k, 6Mohm ± (0.3% reading + 4 digits), 40Mohm ± (0.3% reading + 20 digits). Frequency (electronic): 0.001Hz to 40 MHz. Frequency (electronic) Accuracy: ±(0.1% reading + 1 digits). Frequency (electrical): 10Hz to 400Hz. Frequency (electrical) Accuracy: ±(0.5% reading). Duty Cycle: 0.1% to 99.9%. Duty Cycle Maximum Resolution: 0.1%. Duty Cycle Accuracy: ±(1.2% reading + 2 digits). Diode Test: Test current of 0.9mA typical, open circuit voltage 2.8V DC typical. Continuity Check: Audible signal will sound if the resistance is less than 100 ohm (approx.), test current <0.35 mA. Display: 6,000 count backlit liquid crystal with bargraph.



 

Standard Calibration $75.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the EXTECH INSTRUMENTS EX510. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Bandwidth
Bandwidth is the difference between the upper and lower frequencies in a contiguous set of frequencies within which a component, link or network will operate.

Frequency Span
Frequency Span specifies the range between the start and stop frequencies, also referred to as bandwidth

Noise Figure
Noise Figure the ratio of the signal-to-noise power ratio at the input to the signal-to-noise power ratio at the output.

Ringing
Ringing is an unwanted oscillation of a voltage or current.


Please contact us for your EXTECH INSTRUMENTS EX510 CALIBRATION and/or EXTECH INSTRUMENTS EX510 9 Function Heavy Duty Industrial MultiMeter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: